If you have any combination of exact failure times, right-, left- and interval-censored data, enter your data using a Start column and End column:
For this observation... |
Enter in the Start column... |
Enter in the End column... |
Exact failure time |
Failure time |
Failure time |
Right censored |
time after which the failure occurred |
* (missing value symbol) |
Left censored |
* (missing value symbol) |
time before which the failure occurred |
Interval censored |
time at start of interval during which the failure occurred |
time at the end of interval during which the failure occurred |
This example uses a frequency column as well.
Start End Frequency |