MSA-GRR%太大,怎么改善?
产品/过程特性:直流电阻;指标:≤30%平时试验:是测三次电阻值,(最大值-最小值)/最大值≤30%
现在用的是极差法
原始数据:
单位:Ω
评价值测量值(直流电阻)
12345678910
A2.582.622.562.562.502.582.552.572.512.60
2.572.632.572.552.512.592.562.572.512.61
2.582.622.572.562.502.582.552.572.502.60
B2.562.632.562.562.512.582.552.562.512.60
2.572.622.562.552.492.592.542.572.512.61
2.582.632.562.552.502.592.562.562.502.60
C2.582.622.572.562.512.582.552.562.502.61
2.572.622.562.562.502.582.552.572.512.61
2.582.632.562.552.502.582.552.572.512.60
计算后数据:
零件操作员A操作员B操作员C极差(A,B,C)
10.39%0.78%0.39%0.39%
20.38%0.38%0.38%0.00%
30.39%0.00%0.39%0.39%
40.39%0.39%0.39%0.00%
50.40%0.80%0.40%0.40%
60.39%0.39%0.00%0.39%
70.39%0.78%0.00%0.78%
80.00%0.39%0.39%0.39%
90.40%0.40%0.40%0.00%
100.38%0.38%0.38%0.00%
按照公式计算:GRR%>30%怎么改善?
取样是否可以代表过程偏差?附图可以参考下 取样需要覆盖公差带 阻值太集中了 挺不好调整的,我也试了很多次。 谢谢分享 感谢分享 本帖最后由 小虎 于 2025-8-5 14:32 编辑
现在都是电脑操作怎么会选择极差法?用minitab 均值极差法 或 方差法 跑下来,GR&R约为14%,极差图没有超出控制限的,均值图每个人约一半超出了控制限,合理,但是1、从R图看人员B相对有点波动,看看B的测量手法是否正确,2、怀疑取样不合理或者仪器精度是否足够,3、EV>AV 谢谢分享 {:1_180:}